Checklists prefilled with measuring points
Checklists can be prefilled with measuring points data of the operation's equipment. If such equipment is not found, service order header’s equipment is used to retrieve measuring documents.
General overview
Transaction /PACG/ECM_CL_PREF -Checklist prefilling configuration can be used to customize generation of prefilled checklists containing measuring points data of the operation or service order’s equipment.
Structure T_MEASURE_PTS can be used to map selected measuring point properties with checklist template fields:
The following measuring point data properties are supported by the standard solution and can be used in prefilled checklists without additional enhancements:
Measuring point and measuring position
Upper and lower measurement range limits
Last measurement reading
Prerequisites
Apart from the prerequisites described on the following page: /PACG/ECM_CL_PREF - Checklist prefilling configuration | Preconditions, it is crucial that the activity’s operation has equipment assigned (if not found, equipment is searched on the service order header level). Measuring documents should be maintained for this equipment.
Another equipment determination source
If equipment ought to be determined differently, please implement the following BAdI:
enhancement spot /PACG/ECM_CHKL_PREFILLER → BAdI definition /PACG/ECM_FILL_COMM_STR_ACT_EQ, method GET_EQUIPMENT:
Example checklist template
T_MEASURE_PTS is a table structure with measuring documents data. As this structure is a table, corresponding fields in a checklist template must be part of a series or a table. Find below an example of a series containing text and number input fields used for measuring point data.
Removed meter
Field | Type | Read-only |
---|---|---|
Obis Code | Text input |
|
Meter Reading Result | Number input |
|
Lower Limit | Number input | X |
Upper Limit | Number input | X |
Last Meter Reading Result | Number input | X |
Installed meter
Installed meter series fields can be identical to the replacement fields, but the prefilled data is not necessary in this scenario.
Download
The following checklist template can be downloaded below:
Example checklist template mapping
The FSM checklist template fields should be mapped with relevant fields of structure T_MEASURE_PTS in transaction /PACG/ECM_CL_PREF -Checklist prefilling configuration. An example mapping:
The following checklist instance was generated for an activity whose service order’s equipment contains 4 measuring points, each one is represented as a series in the checklist instance:
The measuring point data from SAP ECC/S4 is reflected in the checklist instance in SAP FSM, based on the maintained mapping:
If you'd like to help us improve the documentation, please provide your feedback using the communication channels listed /wiki/spaces/PFCC/pages/1561427969. Learn about support possibilities here.