Checklists can be prefilled with measuring points data of the operation's equipment. If such equipment is not found, service order header’s equipment is used to retrieve measuring documents.

Table of Contents

General overview

Transaction /PACG/ECM_CL_PREF -Checklist prefilling configuration can be used to customize generation of prefilled checklists containing measuring points data of the operation or service order’s equipment.

Structure T_MEASURE_PTS can be used to map selected measuring point properties with checklist template fields:

The following measuring point data properties are supported by the standard solution and can be used in prefilled checklists without additional enhancements:

Measuring point and measuring position

Upper and lower measurement range limits

Last measurement reading

Prerequisites

Apart from the prerequisites described on the following page: https://proaxia-prod-doc.atlassian.net/wiki/spaces/PFCC/pages/1166737418/PACG+ECM+CL+PREF+-+Checklist+prefilling+configuration#Preconditions, it is crucial that the activity’s operation has equipment assigned (if not found, equipment is searched on the service order header level). Measuring documents should be maintained for this equipment.

Another equipment determination source

If equipment ought to be determined differently, please implement the following BAdI:

enhancement spot /PACG/ECM_CHKL_PREFILLER → BAdI definition /PACG/ECM_FILL_COMM_STR_ACT_EQ, method GET_EQUIPMENT:

Image Added

Example checklist template

T_MEASURE_PTS is a table structure with measuring documents data. As this structure is a table, corresponding fields in a checklist template must be part of a series or a table. Find below an example of a series containing text and number input fields used for measuring point data.

Removed meter

Field

Type

Read-only

Obis Code

Text input

Meter Reading Result

Number input

Lower Limit

Number input

X

Upper Limit

Number input

X

Last Meter Reading Result

Number input

X

Installed meter

Installed meter series fields can be identical to the replacement fields, but the prefilled data is not necessary in this scenario.

Download

The following checklist template can be downloaded below:

View file
nameMeter_Change_new_1.0_Version-36_2021-12-07.zip

Example checklist template mapping

The FSM checklist template fields should be mapped with relevant fields of structure T_MEASURE_PTS in transaction /PACG/ECM_CL_PREF -Checklist prefilling configuration. An example mapping:

The following checklist instance was generated for an activity whose service order’s equipment contains 4 measuring points, each one is represented as a series in the checklist instance:

The measuring point data from SAP ECC/S4 is reflected in the checklist instance in SAP FSM, based on the maintained mapping: