/PACG/ECM_CKDET - Update control key after act. ass. in FSM

Determine the control key assignment per order type depending on internal or external (subcontractor) technician.

 

The external technician indicator is identified in /PACG/ECM_MAINT_USERS in field "Subcontractor". If this "Subcontractor" field is checked, then the control key from the field "External techn." will be used for the operation.



NoUpdOthCK

add-on 200 sp04

If enabled, before changing the service order’s operation’s control key it is checked if the control key currently set on the operation is one of the defined in transaction /PACG/ECM_CKDET (for a given company and order type). If not, the control key won’t be changed.

 

Further explanation:

In transaction /PACG/ECM_CKDET we can define control key determination based on internal or external person. We can have two different control keys per company/order type. In the transaction /PACG/ECM_TKDET we can have more than 2 allowed control keys. Certain control keys should never be changed - all the ones from /PACG/ECM_TKDEF, which are not in /PACG/ECM_CKDET. During operation update, the operation's current control key is checked. If the control key is not defined in /PACG/ECM_CKDET and the new checkbox is enabled, the control key won’t be changed.

If you'd like to help us improve the documentation, please provide your feedback using the communication channels listed /wiki/spaces/PFCC/pages/1561427969. Learn about support possibilities here.