/PACG/ECM_CINC01 – Included categories of Equipment
This setting determines which equipment, based on its category, can be sent to a given FSM company. The equipment “category” field in FSM master data is hard-coded, by default each equipment would be displayed with category “Equipment” and functional location with category “Functional location”. If this does not work, please check the points below:
make sure that field ‘Category’ is added to screen Equipment Details MDM in FSM Admin screen configuration
make sure that transformation for message type /PACG/ECM_EQUI in /PACG/ECM_CLSASSIG - FSM Connector's Outgoing Messages Configuration is set to /PACG/ECM_OUT_EQUIPMENT_1.XSLT. This transformation is the default one for all FSM Cloud Connector versions since add-on 200 SP02
Restrict equipment transfer only to equipment with one of the entered categories. Equipment category is indicated in transaction IE03.
Is Tool | Any equipment type flagged as 'Is Tool' will be sent to SAP FSM as a tool of the type 'equipment'. If required, equipment type tools can have user defined fields and attachments. Learn more about tools: Tools Management and usage |
---|---|
(S4)PACG 200 SP09 Inc.Mea.Pt | During equipment transfer, measuring points assigned to the equipment will be additionally sent. They’ll be visible on the FSM mobile application, on the equipment’s record. Learn more about the integration scope and other setup steps: Measuring points and measurements readings |
(S4)PACG 200 SP09 Incl.Mes.D | During equipment transfer, measurement documents created for the equipment will be additionally sent. They’ll be reflected in FSM as Measurement Readings, visible on the FSM mobile application, on the equipment’s record. Learn more about the integration scope and other setup steps: Measuring points and measurements readings |
(S4)PACG 200 SP09 Not older | Specify how old (in days) measurement documents are relevant for transfer to FSM. Value '0' or empty indicates no limitation. Learn more about the integration scope and other setup steps: Measuring points and measurements readings |
If you'd like to help us improve the documentation, please provide your feedback using the communication channels listed /wiki/spaces/PFCC/pages/1561427969. Learn about support possibilities here.